Baldor AE11 Portable Generator User Manual


 
3-4 Receiving & Installation MN2415
Indoor Location
Continued
4. Keep all fuel and its associated piping away from all components of the engine exhaust
system.
5. The exhaust system should be inspected on a regular basis to assure there are no
toxic exhaust gas leaks. In some areas this inspection may be provided by your local
public service.
6. A carbon monoxide tester may be installed to detect the presence of the deadly gas
during times when you are in the building with the engine running (during testing or
maintenance).
Installation The generator is completely assembled, tested and adjusted at the factory before it is shipped to
you. The procedures presented in this manual are suggestions and it is the responsibility of the
Owner/Operator to arrange for these procedures to be performed by licensed contractors
according to all applicable codes including local codes for your Municipality/City/County and
State. Installation generally includes the following:
1. Secure Generator to concrete pad.
2. Connect Fuel Supply.
3. Electrical Connections power wiring (optional transfer switch) and control wiring.
4. Battery (not included).
5. Ground Connection.
After installation, the post installation checks must be performed prior to starting the engine.
After these checks have been performed and the system operation is verified to be good, refer to
Section 6 Maintenance for periodic checks that must be performed at scheduled intervals to
ensure continued operation with minimal problems.
Secure the Generator
Refer to Table 3-1 for the dimensions and weight of each generator. Mounting bolts in the base
frame secure the generator to the shipping pallet. Remove these bolts, lift the generator and
remove the shipping pallet.
Secure the generator to the concrete pad using anchor hardware (not provided). See Figure 3-1.
Anchor bolts must be long enough to extend through the generator mounting frame.
Table 3-1 Physical Dimensions
Generator
Height
Width
Length
Weight
Generator
Model
H
e
i
g
h
t
Wid
t
h
L
engt
h
Open Enclosed
AE8E/O 36.75 29.00 44.5 255 lbs. 463 lbs.
AE10E/O 36.75 29.00 44.5 316 lbs. 509 lbs.
AE11E 30.50 30.375 46 468 lbs.
AE25ENG 34.00 31.5.0 72 1450 lbs.
AE25ELP 34.00 31.5.0 72 1450 lbs.