Agilent Technologies B Weather Radio User Manual


 
204
Chapter 4: Concepts
Understanding Logic Analyzer Triggering
The Agilent 16715A trigger user interface
Note that a picture (which corresponds to the selected function) is
provided to the right of the trigger function list.
For example, if you want to trigger when a bus pattern is immediately
followed by another bus pattern, you can use the “Find Pattern2
occurring immediately after Pattern1” trigger function, shown in the
following figure.
Pattern2 occurring immediately after Pattern1
Once you have selected this function, you simply fill in the names of
the buses and the patterns. Contrast the previous figure with the
following figure, which is the same trigger created using If/Then
statements. The trigger function is easier to use because the additional
details of the If/Then statements have been hidden. However, if you
want to see the details, you can break down the function.