Agilent Technologies 5951-2827 Tiller User Manual


 
78 Calibration
Table 6-2. Calibration Information
6060B 6063B
Ranges and Calibration
Points
Variables Variable
Values
Power
Supply
Settings
Current
Shunt
Variable
Values
Power
Supply
Settings
Current
Shunt
High Current Range Hi_curr_rng 60 5 V/61 A 100 A 10 25 V/10.5 A 15 A
High Current Offset Hi_curr_offset 0.0282 0.0048
Low Current Range Lo_curr_rng 6 5 V/10 A 15 A 1 25 V/2 A 15A
Low Current Offset Lo_curr_offset 0.0197 0.0032
Voltage Range N/A N/A 61 V/5 A N/A N/A 246 V/0.6 A N/A
Voltage Hi point Volt_hipt 60 240
Voltage Lo point Volt_lopt 2.7 2
Low Resistance Range Lo_res_rng 1 15 V/10.9 A 15 A 24 60 V/1.8 A 15 A
Low Resistance Hi point Lo_res_hipt 1 23.9
Low Resistance Lo point Lo_res_lopt .04 .88
Middle Resistance Range Mid_res_rng 10 10.9 V/15 A 15 A 240 43.6 V/4 A 15 A
Middle Resistance Hi point Mid_res_hipt 30 500
Middle Resistance Lo point Mid_res_lopt 1 24
High Resistance Range Hi_res_rng 1001 60 V/6 A 15 A 24020 *240 V/2 A 15 A
High Resistance Hi point Hi_res_hipt 120 2000
High Resistance Lo point Hi_res_lopt 12 240