975-0082-01-01 7
Features
Bottom panel features
Network Ports Each network port can accept an eight-pin RJ45 plug
attached to a Category 5 (CAT 5) Xanbus network cable. Depending on the
installation, both ports may be required.
Wiring Harness Connector The 20-contact connector supports a wiring
harness (supplied) that connects the AGS to a generator and thermostats.
The wiring harness also provides lines for connecting external generator
shutdown sensors or switches and external generator ON/OFF controls.
Figure 3
AGS Bottom Panel
EQUIPMENT DAMAGE
Only connect the Xanbus Automatic Generator Start (AGS) to other
Xanbus-enabled devices.
Although the cabling and connectors used in this network system are the
same as those used for Ethernet, this network is not an Ethernet system.
Equipment damage may result from attempting to connect these two
different systems.
Failure to follow these instructions can result in minor or moderate
injury.
XANBUS
Gener at or
C
US
RR
CSA 107.1
UL 458
LR 86581
MARINE
WARNING
!
Explosion hazar d.
Do not ins tall in A
loc ation requiring
ignition pr otected
equipmen t. see
man ual .
CONNECT ONLY TO
CLASS 2 ELV CIRCUITS.
SEE MANUAL.
CAUTION
!
20-contact generator
connector port
Two 8-pin RJ-45 Xanbus
network ports
Figure 4
Wiring Harness Connector
20-contact wiring harness
connector