York P4LBX20F19001 Patio Furniture User Manual


 
21
IDLE STATE
THERMOSTAT CALLS FOR HEAT
SAFETY CHECK FOR FLAME
(5 SEC.)
BURNER MOTOR & IGNITOR START
SOLENOID VALVE OPENS
TRIAL FOR IGNITION
15 SEC.
BURNER FLAME MONITORED
CARRYOVER STATE
Provides continuous spark
LED diagnostic light ON
Start Carr
y
over Timer
CARRYOVER TIMER EXPIRES
RUN STATE
I
g
nitor turns off.
THERMOSTAT SATISFIED
R7184 SHUTS OFF:
Burner Motor
Solenoid Valve
LED Dia
g
nostic Li
g
ht
RETURNS TO IDLE STATE
FLAME
FLAME
FLAME
FLAME
NO FLAME
NO FLAME
FLAME LOST
FLAME LOST
REMAINS IN IDLE STATE
R7184
SEQUENCE of
OPERATION
LOCKOUT STATE
R7184:
Shuts off burner motor
Shuts off igniter
Shuts off Solenoid Valve
Fast Flashes LED Diagnostic
Li
g
ht
TO EXIT LOCKOUT
PRESS RESET
RECYCLE TIMER STARTS
R7184:
Shuts off Solenoid Valve
Shuts off Ignitor
Shuts off Burner Motor
Slow Flashes LED diag-
nostic li
g
ht
RECYCLE TIMER EXPIRES
(60 SECONDS
FLAME LOST