Xantrex Technology MS2000 Portable Generator User Manual


 
Installation
36 975-0126-02-01
Step 8: Performing Checks Prior to Initial Start-Up
Before testing your installation, ensure these conditions are met:
Chassis and AC grounds are properly installed.
AC input connections and AC output connections are wired correctly on the
terminal block and not reversed.
Positive (+) battery cable is connected to the house bank positive (+) battery
terminal through the DC fuse and disconnect switch or DC circuit breaker.
Negative () battery cable is connected to the house bank negative () battery
terminal.
House battery voltage is within the proper range for this unit
(10.315.3 volts DC).
DC disconnect switch or breaker is turned off.
Echo Charger disconnect switch is off or fuse is removed.
Echo Charger connections are correct: positive (+) cable runs from the Echo
Charger to the positive terminal of the engine battery.
Both the house battery and the engine battery negative terminals are
connected to the engine negative terminal/bus.
AC input and output breakers are turned off.
All connections are tight.