Xantrex Technology MS2000 Portable Generator User Manual


 
Installation
22 975-0126-02-01
Connecting the AC Output Wires
To make the AC output wiring connections:
1. Remove one of the AC knockouts from the front or side of the unit. Do not
leave the knockout inside the wiring compartment
2. Install a strain-relief clamp in the AC knockout.
3. Run the AC wiring through the strain-relief clamp.
4. Strip approximately 2 inches (50 mm) off the jacket from the AC cable and
separate the three wires.
5. Using the 1/4" blade slot screwdriver, loosen the wire attachment screws on
the AC output terminals. Do not remove the screws.
6. Insert the line wire into "L", the neutral wire into "N", and the ground wire
into ground (
), as shown in Figure 6. Observe the color codes described in
Table 4.
7. Tighten the wire attachment screws. Leave some slack wire inside the wiring
box.
8. Secure the strain-relief clamp on the AC output cable jacket.
9. Attach the wiring compartment cover panel and tighten the four screws.
10. Connect the outgoing AC wires to an AC load panel equipped with circuit
breakers.
Figure 6
AC In and AC Out: Hardwiring Completed
CAUTION: Risk of equipment damage
Do not connect the output of the inverter to any incoming AC source.
Important:
The applicable installation code may not allow you to run the AC
input and AC output wiring through the same AC knockout.