6. Mount the sensor directly on top of the ring terminal, as shown in Figure 14,
and firmly tighten the terminal nut.
7. Check to ensure that the sensor and all wires are held firmly and cannot be
moved.
8. Turn the battery switch on again (if you opened it in Step 2).
9. Route the sensor cable to the inverter/charger and plug it into the Battery
Temp jack, as shown in Figure 15. Secure the cable along its length.
WARNING: Fire hazard
In this procedure, you must install the DC wire on the battery terminal first. Then the
sensor is installed on top of the DC wire. This sequence is required to provide the best
connection to the battery and to ensure correct performance of the sensor.
Figure 15
Connecting the BTS Cable to Battery Temp. jack