RIDGID Metal Detector Metal Detector User Manual


 
Ridge Tool Company
4
Signal Strength..............Non-linear in function. (2000
is 10x higher than 1000, 3000
is 10x higher then 2000, etc.)
Operating Environment
Temperature................-4°F to 122°F (-20°C to 50°C)
Humidity ......................5% to 95% RH
Storage Temperature .....-4°F to 140°F (-20°C to 60°C)
Default Settings
The default settings for the locator are:
Measured Depth units = Feet & Inches,
Volume = 2 (two settings above mute),
Backlight = Auto
512 Hz (Sonde) Default Mode
Optional Settings
The optional settings for the locator are:
Measured Depth units = Meters,
Volume = 0 (mute) to 5,
Backlight = On, Off
Mode: Active Line Trace, Passive Line Trace
Standard Equipment
Optional Equipment
NaviTrack
®
II
Nominal and Exact Frequency Values (NaviTrack II)
Sonde 16 Hz 16
512 Hz 512
640 Hz 640
850 Hz 850
8 kHz 8192
16 kHz 16384
33 kHz 32768
Active Line 128 Hz 128
Trace 1 kHz 1,024
8 kHz 8,192
33 kHz 32,768
200 kHz 200000
262 kHz 262,144
Passive Line 50 Hz
Trace (9th harmonic) 450
60 Hz
(9th harmonic) 540 Hz
(European) 93 kHz 93,696.0
93 kHz -B 93,622.9
(See note on 93 kHz Frequencies on page 17.)
Catalog
No. Description
14818 NaviTrack Line Transmitter – 10 Watt
20168 NaviTrack Brick Transmitter – 5 Watt
20503 Inductive Clamp (4.75)
16728 Remote Transmitter (Sonde)
19793 Float Sonde (Package of 2)
12543 Surface Markers and Clip
Catalog
No. Description
96967 NaviTrack II Locator
12543 Surface Markers and Clip
22388 Molded Carrying Case
Operator’s Manual (Downloadable @ www.navitrack.com)
Quick-Start Guide (Downloadable @ www.navitrack.com)
Frequencies
Default Frequencies
Sonde ........................512Hz
Active Line Trace.......128Hz 1kHz, 8kHz, 33kHz,
262kHz (European: 93kHz)
Passive Line Trace....60Hz (9th)
Optional Frequencies
Sonde ........................16Hz, 640Hz, 850Hz, 8kHz,
16kHz, 33kHz
Active Line Trace.......200kHz
Passive Line Trace....50Hz (9th)