VOYAGEUR GRAND Wood Insert
R
8. Thepowercordisnowdisconnectedfromtheblower
control plate. Pull the cord out through the right side
of the appliance.
Route Cord Through
Retainer Clip
Grommet
9. Insert the power cord throught the left side of the
appliance in the hole contains the grommet. Pull the
connection ends to the right side. Route the power
cord through the retainer clip.
Strain Relief
10. Replace the strain relief on the power cord in the
same position as before. Locate the indentation on
thecordmadebythestrainrelief.Oncereplaced,
pushthestrainreliefbackintothecontrolplate.
White Wire
Black Wire
Fiber
Wrapped
Wire
Green
Grounding
Wire
11.Connectthewhitewireonthepowercordintothe
berwrappedwireonthewireharness.Connectthe
blackwireonthepowercordtothewhitewireonthe
rheostat. Re-attach the green ground terminal to the
control plate.
12.Insert the control plate assembly back into the
applianceasshown.Tilttheassemblyforwardand
then lift up and rotate the bottom towards the front
of the appliance at the same time ensure that the
snapdischolderisproperlyseated.Secureplate
to the appliance.
Figure 45.1
Figure 45.2
Figure 45.3
Figure 45.4
Figure 45.5
Route Wires through Retainer Clip
Replace Screws in Hold Down Bracket
13.Push in the blowerand hold down bracket into
appliancematchingupthetabonthebracketand
placementslot onthe appliance.Secure bracket
and reconnect blower wires (no polarity to worry
about) routing wires through the retainer clip.
Figure 45.6