Radware VOYA-GRAND-PMH Lawn Mower User Manual


 
Page 38
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
Ovalizingroundstainlesssteellinerstoaccommodatethe
linerpassingthroughthedamperregionofareplaceisan
allowable and acceptable practice.
Ensure that the ovalization is minimized to the extent
requiredtotthroughthedamper.
J. Ovalizing Round Stainless Steel Liners
FireRisk.
DoNOTpackinsulationorothercombustibles
between spacers.
• ALWAYSmaintainspeciedclearancesaround
venting and spacers.
• Installspacersasspecied.
Failuretokeepinsulationorothermaterialawayfrom
ventpipemaycausere.
WARNING
K. Chimney Height / Rise and Run
TobesurethatyourQuadra-Fireinsertburnsproperly,the
chimney draft (static pressure) should be approximately -0.10
incheswatercolumn(W.C.)duringahighburnand-0.04
inchesW.C.duringalowburn,measured6inches(152mm)
above the top of the insert after one hour of operation at each
burn setting.
NOTE:Theseareguidelinesonly,andmayvarysomewhat
for individual installations.
• Thisproductwasdesignedforandtestedona6inch
(152mm) chimney, 14 to 16 feet (4.27-4.87m) high, (in-
cludes appliance height) measured from the base of the
appliance.
• Thefurtheryourstackheightordiametervariesfromthis
conguration,thepossibilityofperformanceproblemsex-
ists.
• Chimneyheightmayneedtobeincreasedby2
- 3% per
each 1000 feet (304.8m) above sea level.
• It is not recommended to use offsets or elbows at altitudes
above 4000 feet (1219.2m) above sea level or when there
areotherfactorsthataffectuedraft.
FireRisk.
Thisappliancereliesuponnaturaldrafttooperate
properly.
• Chimneyheightsexceeding25feet(7.62m)from
base of appliance may create an over-draft situation.
• Overdraftconditionmaycreateover-ring.
Over-ringmayignitecreosoteand/ordamageappli-
ance and chimney.
WARNING
FireRisk.
Failuretoinstallafullrelinemaycause:
• Creosoteaccumulationcreatingincreasedriskof
chimneyre.
• Loseprotectiontocombustiblesurfacesfromthe
linerincaseofre.
• Poorperformanceandstart-ups.
• Lessaccesstochimneyforrequiredmaintenance.
WARNING