VOYAGEUR GRAND Wood Insert
R
Thefollowingmodicationsoffactory-builtreplacesare
permissible:
• Thereplacemustnotbealtered,exceptthatthedamper
may be removed to accommodate a direct-connect starter
pipe or chimney liner,
• External trim pieces which do not affect the operation
ofthereplacemayberemovedprovidingtheycanbe
storedonorwithinthereplaceforreassemblyifthe
insert is removed.
• Thepermanentmetalwarninglabelprovidedinthe
componentpackmustbeattachedtothebackofthe
replace,withscrewsornails,statingthatthereplace
may have been altered to accommodate the insert,
and must be returned to original condition for use as a
conventionalreplace.Figure 37.2.
• Manufacturerdesignedadjustablesupportkitcanbe
ordered from your dealer.
• Finalapprovalofthisinstallationtypeiscontingentupon
theauthorityhavingjurisdiction.
Damper SmokeShelforBafe
EmberCatches FireGrate
ViewingScreen/Curtain Doors
Thefollowingpartsmayberemoved:
LINER CONNECTOR
FLUE
GAS
DIRECTION
CRIMPED
END
TOWARDS
STOVE
Figure 37.1
H. Altering the Fireplace
G. Securing Chimney Components
All joints should be securedwith 3 sheet metal screws or
rivetsperpipemanufacturersinstructions.Thesectionsmust
be attached to the insert and to each other with the crimped
(male) end pointing toward the insert. Figure 37.1.
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Heath & Home Technologies
250-2061
5.5 in. width x 2 in. height
NON. ANOD. ALUM BLACK LETTERS ON SILVER
with 1/8 in. holes on both sides.
Black letters
Figure 37.2
WARNING! Risk of Asphyxiation!
• DONOTCONNECTTHISAPPLIANCETO
ACHIMNEYFLUESERVICINGANOTHER
APPLIANCEORTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Thismayallowuegasestoenterthehouse.
I. Factory-Built Sold Fuel Fireplace
Apermitmayberequiredforinstallations,nalapprovalis
contingentoftheauthorityhavinglocaljurisdiction.Consult
insurancecarrier,localbuilding,reofcialsorauthorities
having jurisdiction about restrictions, installation inspec-
tion, and permits.
Inspecttheexistingreplaceandchimneyforanydamage
orawssuchasburnouts,metalorrefectorywarping.
InspectiontoaminimumofNFPA211LevelIIisrecom-
mended.Allrepairsmustbemadepriortoinstallingan
insert.Thereplacemustbestructurallysoundandbe
able to support the weight of the solid-fuel insert
Thefactory-builtchimneymustbelistedperUL127orULC
610-M87 for all installations. Install thermal protection per
this appliance listing requirements.
A full height 6 inch diameter stainless steel full height
listed chimney liner must be installed meeting type HT
(2100°F) requirements per UL 1777 (USA) or ULC S635
with “0” clearance to masonry (Canada). The full liner
must be attached to the insert ue collar and to the top
of the existing chimney.
Theuelinertopsupportattachmentmustnotreducethe
airowfortheexistingair-cooledchimneysystem.Re-
install original factory-built chimney cap only.(SeeSec-
tionF.,PrefabricatedMetalChimney)
Topreventroomairpassagetothechimneycavityofthe
replace,sealeitherthedamperareaaroundthechimney
linerortheinsertsurround.Circulatingairchamber(i.e.in
asteelreplacelinerormetalhearthcirculator)maynot
beblocked.Theairowwithinandaroundthereplace
shallnotbealtered,blockedbytheinstallationoftheinsert.
(i.e. no louvers or cooling air inlet or outlet ports may be
blockedbytheinsertortheinsertsurround.
See“H.AlteringtheFireplace”formodicationsallowedfor
factory-builtreplaces.