Page 22
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
D. Blower Replacement
1. The grille on the blower access assembly is hinged.
Swing the grille downward to expose the 2 screws.
Figure 22.1.
2. Remove the 2 screws from the blower access assembly
and slide assembly away from the appliance.
3. Disconnect the wires from the blower.
4. Removethe2screwsfromtheholddownbracketand
pulltheblowerandbracketforward.
5. Removetheblowerfromtheholddownbracket.
6. Remove the protection guards from each end of the
blower.
7. Re-install in reverse order. Be certain that the hold down
bracket’s screws are completely seated in the grom-
ments.Insertthelocatingtabintheholddownbracket
into the placement slot.
Shock Risk.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Routecordawayfromappliance.
•
DoNOTroutecordunderorinfrontofappliance.
CAUTION
Figure 22.1
DoNOTallowhotcoalsoremberstooverowashlip
• May melt protective wire coating on fan power
cordcausingelectricalshort,reorinjury
Fire Risk.
WARNING
Blower Access
Assembly
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Hold Down
Bracket
Remove Screws from Hold
Down Bracket and Pull
Forward
Placement Slot
CAUTION! Unplug appliance
from power source before
replacing any components.