Icom IC-R8500 Weather Radio User Manual


 
36
10
COMMAND LIST
•‘OK message from IC-R8500 to PC •‘NG message from IC-R8500 to PC
Memory channel contents set & write (1A 00)
The above data packet is an example of programming
the following into memory channel 123 of bank num-
ber 19:
Frequency: 1,234,567,890 Hz
Mode: FM
Tuning step:199.5 kHz (programmable step)
Attenuator: 10 dB
Scan select: specied
Scan skip: specied
Memory name: IC-R8500
Scan skip and select channels
FE FE E0 4A FB FD
Preamble code
PCs address
IC-R8500s address
OK code
End of message code
FE FE 4A E0 1A 00 1901239078563412050113951910034943205238353030 FD
Memory name
Tuning step
Mode(Sc)
FrequencyCH no.
Bank
SCN
ATT
Preamble code
IC-R8500s address
PCs address
Command number
Sub command
(IC-R8500s command)
10 Hz
1 Hz
1 kHz
100 Hz
100 kHz
10 kHz
10 MHz
1 MHz
1 GHz
100 MHz
End of message code
ASCII code
BCD code area
(only needed when 13
is selected)
IC-R8500
FE FE E0 4A FA FD
Preamble code
PCs address
IC-R8500s address
NG code
End of message code
Comment
number
Scan select Scan skip
00 OFF OFF
01 OFF Specied
02 Specied OFF
03 Specied Specied
Clearing the specied channel data
(Memory channel contents set & write)
Special bank number and channels (bn)
FE FE 4A E0 1A 00 19 0 1 2 3 FF FD
Preamble code
PCs address
IC-R8500s address
Command number
End of message code
Blank data
Memory channel
number
IC-R8500s command
Bank number
Special bank Bank number
FREE
20
AUTO
21
SKIP
22
PROG
23
PRIO
24
Remarks
For programmed
scan, channel num-
bers are as follows:
0P1=00, 0P2=01,
1P1=02, 1P2=03,
etc., up to 9P1=18
and 9P2=19.
There is only one
channel in the prior-
ity bank.
Gain and level data (gd; BCD data)
AF GAIN
SQUELCH
Max.
counterclockwise
0000
Max.
clockwise
0255
IF SHIFT
APF control
Max.
counterclockwise
0000
Max.
clockwise
0255
center
0128