A SERVICE OF

logo

733
Chapter 35 Free-Run Timer
1.Overview
Chapter 35 Free-Run Timer
1. Overview
The free-run timer consists of a 16-bit timer (up counter) and control circuits.
The free-run timer can be used with the input capture and the output compare.
2. Features
Format: 16-bit up counter
Quantity: 8 (free-run timer 0 up to free-run timer 7)
Clock source: 4 internal clocks (1/4, 1/16, 1/32, and 1/64 of CLKP)
External clock (CK)
Clear factor of the count:
Software
Reset
Compare-match (match of the compare-register value and the count value of the free-run timer)
Operation start/stop: operations can be started/stopped with software.
Interrupt:
Overflow interrupt
An interrupt generated when the compare clear register value and the count value of the free-run timer
match.
Count value: Readable/writable (write is only possible when the counting stops)
Others: Operates from immediately after reset.
Free Run Timer to ICU/OCU mapping:
Free-run timer 0 and input capture 0/1 co-operate
Free-run timer 1 and input capture 2/3 co-operate
Free-run timer 2 and output compare 0/1 co-operate
Free-run timer 3 and output compare 2/3 co-operate
Free-run timer 4 and input capture 4/5 co-operate
Free-run timer 5 and input capture 6/7 co-operate
Free-run timer 6 and output compare 4/5 co-operate
Free-run timer 7 and output compare 6/7 co-operate
or
Clear
Internal clock
or
External clock
OverflowUp counter