Xantrex Technology GT 2.5-DE, GT 3.8-DE, GT 2.8-SP, GT 3.8-SP Portable Generator User Manual


 
Mounting the Inverter
975-0253-01-01 2–15
Mounting on Wallboard, Siding or Concrete
To mount the GT Inverter to wallboard, siding, or concrete:
1. Locate the area where the GT Inverter is to be installed.
2. Install backing support material if required.
3. Using a level, place the mounting bracket against the wall surface so that the
bottom edge of the bracket is at least 130 cm (51 inches) above the ground.
Position the top edge of the bracket a minimum of 34 cm (13.5 inches) below
any ceiling or roof. See Figure 2-7.
4. Mark the location for mounting screws if using a wall stud for support. At
least four mounting screws and anchors are needed for concrete installations
or wallboard installations where no wall studs are available for support.
5. Remove the bracket and drill the holes using an appropriately sized drill bit.
Drill appropriately sized holes for screws or anchors.
6. Secure the bracket to the supporting surface using at least two screws and
washers.
Figure 2-7
Installing the Mounting Bracket using Plywood Support
Single GT Inverter Multiple GT Inverters
130 cm (51")
130 cm (51")
At least 2 screws
with washers to
secure bracket
to plywood
16.5 cm (6.5")
Ground/floor
Ground/floor
34 cm (13.5”)