Xantrex Technology 975-0057-01-01 Yard Vacuum User Manual


 
Troubleshooting
5-4 975-0057-01-01
Run time is
less than
expected.
Internal battery is not
fully charged.
AC appliance power
consumption is higher
than expected.
Recharge using the AC Charger,
until green Charging Status light is
steady.
Check AC appliance power or
wattage rating (or current draw for
12 V DC appliances) and compare
with Table 3-1 on page 3–5 and
Table 3-2 on page 3–9.
Charging
Status light is
Off when AC
Charger is
connected
No AC power at the
AC wall outlet.
AC Charger is faulty.
Ensure power is available at the AC
wall outlet.
Replace the AC Charger.
Green
Charging
Status light is
flashing
(indicating
recharging)
and Battery
Charge (%)
does not turn
on.
Battery Charge (%)
reading on digital
display is only
accurate when the
XPower Powerpack
has been disconnected
from all appliances
and all charging
sources for fifteen
minutes.
Unplug the charging sources and any
appliances and let the XPower
Powerpack rest for 15 minutes to
obtain an accurate reading.
Green
Charging
Status light is
still flashing
and hasn’t
changed to
steady after 50
hours of
charging.
The voltage at the AC
wall outlet is less than
120 V AC.
Internal battery is
permanently damaged.
Use AC wall outlet that supplies 120
V AC.
Replace the battery.
Table 5-1
Troubleshooting reference