Xantrex Technology 300 C Portable Generator User Manual


 
Jump-starting a Vehicle or Boat Engine
20
If the clips are not properly connected, the reverse
polarity alarm sounds and the Battery Clips Connected
Improperly (red light) illuminates.
8. Remove the red positive (+) clip first, and then the black
negative clip (–) to cancel the alarm.
9. Repeat steps 1, 5, 6, and 7.
After the clips are properly connected and the Battery
Clips Connected Properly (green light) is illuminated,
make sure that Jazz PP 300 C and the jump-start cables
are clear of belts and fans before attempting to start the
engine.
10. Remove the red positive (+) clip and then the black
negative (–) clip from the vehicle’s battery terminal.
11. Remove the jump-start cables from the Jumper Cable
Port.
WARNING: Explosion
Do not remove the jump-start cables from the Jumper
Cable Port when the positive and negative clips are
connected to the vehicle’s battery terminals. Removing
the jump-start cables from the Jumper Cable Port while
they are connected to the vehicle’s battery terminals
disables the jump-start safety feature and could result in
sparking and explosion.
Important:
Recharge the Jazz PP 300 C as soon as
possible after each use. See “Recharging the Jazz PP 300 C
Battery” on page 26.
Jazz 300.book Page 20 Thursday, February 28, 2002 11:36 AM