TRANSPORTING
PERIODIC OPERATION AND
INSPECTION
When furnishing the generator as emergency
electric power source, periodic operation and
inspection are needed.
Fuel and engine oil will be deteriorated with time,
and this causes that the engine is difficult to start
and as the results improper engine operation and
fault.
Since the fuel will be deteriorated
with time,
replace fuel with fresh
one periodically;
once every three (3) months is
recommended.
CAUTION
(a) Check the fuel, engine oil and air cleaner.
(b) Start engine.
(c) With appliance such as lightings activated,
run the engine for over ten minutes.
(d) Check for the following items;
Proper engine running.
Adequate output and the indicator lamp
turned on properly.
Key switch and fuel cock normally
operated.
No leakage of engine oil and fuel.
When transporting the generator, make sure that
the fuel should be drained from the tank.
(a) Turn the fuel cock to the CLOSE position.
(b) Drain the fuel from the tank.
To prevent fuel spillage due to the
vibration and impact, never transport
the generator with the fuel filled in the
tank.
Secure the tank cap thoroughly.
To avoid the risk of the
fuel
flammability, never leave the generator
in an area exposed to direct sunlight or
high temperatures for a long time.
Keep the fuel in the exclusive
fuel
storage tank made by steel when
transporting.
WARNING
(c) Secure the tank cap.
Do not place any heavy objects on the
generator.
Select and place the generator in the
proper position of the transport vehicle
so that the generator not be moved or
fallen down.
Fix the generator with rope as necessary.
CAUTION
OPEN
CLOSE