Subaru RGD3300H Portable Generator User Manual


 
8
ENGLISHFRANÇAISEESPAÑOL
OPERATING PROCEDURES
(See Fig.
33
,
44
)
1. STARTING THE GENERATOR
Check the oil level before each operations
as outlined on page 5.
CAUTION
Do not run the starting motor over 5
seconds continuously.
If the engine fails to start, return the
key to the RUN position and wait about
10 seconds then start again.
When starting the engine by recoil starter,
set the key switch at the RUN position
and pull the starter handle.
CAUTION
(a) Before starting (See Fig.
33
-
qq
thru
tt
)
Make sure the appliance is disconnected.
Turn the fuel cock to OPEN position.
(See Fig. 3-q)
q OPEN w CLOSE
Turn the AC circuit breaker to the OFF position.
(See Fig. 3-w)
q ON w OFF
First of all set the speed adjuster to the STOP
position (See Fig. 3-e), then move it to the
starting position.
q SPEED ADJUSTER
w STOP position
e 1/2
r START position
Set speed adjustment lever either to 1/2 START
or max. START position, as desired or
necessary. (See Fig. 3-r)
Starting at a lower speed will help to prevent
exhaust smoke.
Move speed adjuster to the "START/RUN"
position.(See Fig. 3-t)
Now, the engine is ready for starting.
(b) Starting (See Fig.
33
-
yy
thru
oo
)
Do not connect defective appliances
including lines and plugs.
Be sure appliances are not connected
to generator when starting up.
Starting the generator with an
appliance connected could result in
damage to the generator and/or
appliance and in personal injury.
CAUTION
Insert the key, and depress and turn it to
position RUN (See Fig. 3-y)
q STOP w RUN e START
Turn the key to position START.
(See Fig. 3-u)
Release the key as soon as the engine runs.
The starting key must spring back to position
RUN and remain there during engine operation.
The battery charge and oil pressure lights
should extinguish directly after the engine
starts. The display lamp q lights up to show
that the engine is running.(See Fig. 3-i)
q Engine Operation Indicator Light
w Battery Charge Indicator Light
e Oil Pressure Warning Light
r Engine Temperature Warning Light
Prior to starting up again, the key has to be
returned to position STOP. When the engine is
running the starter repeat lock in the ignition
switch will prevent the starter from engaging
and suffering damage.
(See Fig. 3-o)
Do not run the engine in closed or badly
ventilated rooms - danger of poisoning !
Before starting the engine, ensure that
no-one is in the danger area close to the
engine or equipment, and that all
protective guards are fitted.
WARNING