Subaru RGD3300H Portable Generator User Manual


 
7
ENGLISHFRANÇAISEESPAÑOL
(a) Attach terminals to a lead-acid battery already
charged. Mount the battery onto the position as
specified below, with its terminals facing inward.
(b) Insert each long bolt through the specified hole,
its tip pointing outward.
(c) Put the supporting arm on the long bolts and
tighten with the butterfly nuts. (Push the lead-acid battery all the way inward.)
(d) Arrange the wiring so that it won't be damaged by possible vibration caused by the engine.
(e) Only after checking that the engine's starter key is in the "OFF" position, securely connect the red cable,
to the positive (+) terminal. And then connect the other cable to the negative (-) terminal.
Red cable : to the (+) terminal
Black cable : to the (
-
) terminal
Should the connection be made in incorrect manner, the engine will be broken.
CAUTION
RED CABEL
RED
CABEL
5
LESS THAN
205 mm [8.1 in.]
LESS THAN
260 mm [10.2 in.]
LESS THAN
130 mm [5.1 in.]
2
3
4
5
1
2
4
3
Spring washer
1 Butterfly nut
Battery bolt
Battery stay
Accessory parts
Bolt and Nut
6. BATTERY INSTALLATION
Recommended Battery (Lead-acid type)
Capacity : 12V-36A h or larger
Size (Max) : 10.2 x 5.1 x 8.1 [in.]
[L x W x H] : 260 x 130 x 205 [mm]
Make and Model
Interstate : SP-40 model