5. GROUNDING THE GENERATOR
To ground the generator to the earth, connect
the grounding lug of the generator to the
grounding spike driven into the earth or to the
conductor which has been already grounded
to the earth. (See Fig. 2-t)
q GROUNDING SPIKE
If such grounding conductor or grounding
electrode is unavailable, connect the
grounding lug of the generator to the
grounding terminal of the using electric tool or
appliance. (See Fig. 2-y)
q GROUND TERMINAL
4. CHECK GENERATOR SURROUNDINGS.
Make sure you review each warning in
order to prevent fire hazard.
Keep area clear of in flammables or
other hazardous materials.
Keep generator at least 3 feet (1 meter)
away from buildings or other structures.
Only operate generator in a dry, well
ventilated area.
Keep exhaust pipe clear of foreign
objects.
Keep generator away from open flame.
No smoking!
Keep generator on a stable and level
surface.
Do not block generator air vents with
paper or other material.
WARNING
Make sure you review each warning in
order to prevent fire hazard.
Do not refill tank while engine is
running or hot.
Close fuel cock before refueling with
fuel.
Be careful not to admit dust, dirt, water
or other foreign objects Into fuel.
Wipe off spilt fuel thoroughly before
starting engine.
Keep open flames away.
WARNING
3. CHECKING COMPONENT PARTS
Check following items before starting engine:
Fuel leakage from fuel hose, etc.
Bolts and nuts for looseness.
Components for damage or breakage.
Generator not resting on or against any
adjacent wiring.
NOTE
If a double fuel filter system is provided ,
wait for a short time after replenishing fuel
(approx. 1 to 2 minutes) for automatic
bleeding to be completed.
All diesel fuels which satisfy the following
specifications are suitable:
EN 590 or
BS 2869 A1 / A2 or
ASTM D 975 - 1D / 2D
Remove fuel tank cap.
Before the first start or if the fuel tank has been
run dry, completely fill the fuel tank with diesel.
The bleeding of the fuel system is automatically.
Close and fix fuel tank cap.
RGD3300H . . . . . . . . . . . . . . . . . 12.0
RGD5000H . . . . . . . . . . . . . . . . . 12.0
Fuel tank capacity :
(L)
At temperatures below 0 °C, winter-grade fuel
should be used or paraffin added to the fuel well
in advance.
Wipe off any spilled fuel before starting the
engine.(See Fig. 2-r)
Winter fuel
20 %
50 %
Summer fuel
20 %
30 %
50 %
Lowest ambient temperature
when starting, in °C
up to
up to
up to
up to
-10
-15
-20
-30
0
-10
-15
-20
Paraffin content for: