3. FULL POWER SWITCH
Select the voltage using the FULL POWER SWITCH in
accordance with the electrical appliance.
Refer to TABLE 2.
Change the FULL POWER SWITCH after turning
the AC circuit breaker to "OFF".
CAUTION
NOTE
Voltmeter always indicates the lower voltage whichever the FULL POWER SWITCH is set.
120V
120V
240V
Switch position Lower Voltage Receptacle Higher Voltage Receptacle
120V Activated full rated output
N.A
120/240V Activated half of rated output Activated full rated output
TABLE 2
4. STOPPING THE GENERATOR
(a)
Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator.
(b) Allow the engine about 3 minutes to cool down at no load before stopping.
(c) Move the speed adjustment lever back to the STOP position.
The engine cuts out. (See Fig. 4-y)
q SPEED ADJUSTER
w STOP position
Be sure to turn the key switch to STOP position after stopping.