Subaru R1100 Portable Generator User Manual


 
– 35 –
Tightening torque : 3.0
-
5.0 N
m
30
-
50 kgf
cm
(2.2
-
3.7 ft
lbs)
Stator
Rear cover
Rear cover
Stator bolt
(M5 : 2pcs.)
5-4-9 Rear cover, stator
Install the rear cover of the generator and stator into the
blower housing.
5-4-10 Rear cover, stator
Install the Brush holder.
M5 x 14mm Screw 1pce.
Install the rear cover to the blower housing.
M6 x 25mm Flange bolt : 3pcs.
Tightening torque : 10.0
-
11.0 N
m
100
-
110 kgf
cm
(7.4
-
8.1 ft
lbs)
NOTE: Make sure of the direction of rear cover
during installation.
Tighten Stator bolts (M5 : 2 pcs.) to the specified
tightening torque, after installing Rear cover onto
Blower housing.
Brush holder