Subaru R1100 Portable Generator User Manual


 
– 15 –
4-3) MEASURING INSULATION RESISTANCE
4-2) AC OUTPUT MEASURING
SWITCH
LOAD
TO AC RECEPTACLE
F
A
~
V
~
Use a circuit above for measuring AC output. A hot plate or lamp with a power factor of 1.0 may be used as a
load. Adjust the load and rpm, and check that the voltage range is as specified in the following table at the
rated amperage and rated rpm.
(1)
Connect the megger tester across either one of the two
output terminals of the AC receptacle and ground
terminal to measure the insulation resistance.
Measure it with the AC breaker on. An insulation
resistance of 1 M or more is normal.
Original insulation resistance at the time of shipment
from the factory is 10 M or more.
If it is less than 1 M , disassemble the generator and
measure the insulation resistance of the stator, rotor
and control panel individually.
Rated voltage 60Hz-120V
Voltage range 120
-
128
230
-
246
50Hz-230V
240
-
256
50Hz-240V