Subaru Robin Power Products RGV6100 Portable Generator User Manual


 
-
71
-
2-4-6 CHECK THE DC COIL
Check the resistance between two brown leads from stator with a circuit tester.
If the resistance reading is much larger or smaller than the specified value, the DC coil of the stator is
faulty. Replace stator with a new one.
2-5 IDLE CONTROL (OPTIONAL EQUIPMENT)
2-5-1 ENGINE SPEED IS NOT INCREASED
WHEN A LOAD IS APPLIED
(1) Inspect the solenoid bracket. Check the bend
angle of solenoid bracket. If the bracket is dis-
torted, correct the angle with proper tool.
(2) Check the wattage of load applied to the gen-
erator. If the generator is loaded over the rated
wattage, the engine speed can not be in-
creased. Most induction loads such as elec-
tric motor or electric tools or welding machine
require three to five times large wattage of their
ratings at starting. This starting wattage must
not exceed the rated output of the generator.
(3) Check the slow set r.p.m.
The normal idling speed by the IDLE CON-
TROL is as follows : 2000 to 2200 r.p.m.
The above speed setting is for cold engine con-
dition. If the engine speed is out of adjusting
range of the adjusting screw, move the sole-
noid backward.
Fig. 2-16
Fig. 2-15
Table. 2-5
SPEED CONTROL LEVER
ADJUSTING SCREW
NOTE 2 : ”Continuity” means forward direction characteristics of the diode, and different from short
circuit condition (in which a pointer of the tester goes out of its normal scale), shows resis-
tance to some extent. When results of the checking indicates failure even in one section,
replace with a new one.
NOTE 3 : Simpson brand analogue testers have the characteristics as same as the digital circuit tester.
LEDOMNOITACIFICEPSECNATSISER
1014VGR zH06V042/V02141.0
1016VGR zH06V042/V02111.0