9-4 STATOR
Disengage connectors on the wires from stator
and check the resistance between wires with a
“Dr. Robin” or a circuit tester referring to the fol-
lowing table.
NOTE : If the circuit tester is not sufficiently accurate, it may not show the values given and may give
erroneous readings. Erroneous readings will also occur when there is a wide variation of resis-
tance among coil windings or when measurement is performed at ambient temperatures differ-
ent from 20
°
C (68
°
F).
Fig. 9-4
Table. 9-1
LEDOM
noitacificepSgnidniWCA
resnednoC
gnidniW
zHegatloVdeR/etihWeulB/kcalBwolleY/wolleY
0082VGR 06V042/V021,V02185.085.076.1
0014VGR 06V042/V021,V02125.025.099.0
0016VGR 06V042/V021,V02152.052.085.0