13
-
NOTE : If your generator has receptacles pecu-
liar to your country, Table 5-2 does not
apply.
Caution :
The duplex 120V receptacle is protected by a
GFCI (Ground Fault Circuit Interrupter).
GFCI shuts off the output current from the
duplex 120V receptacle when a ground fault
occurs in the generator or the appliance.
Please note that other receptacles are not pro-
tected by GFCI.
5-2-7 GFCI RECEPTACLE
After starting the engine, check the GFCI for proper functioning by the following test procedure.
Push yellow TEST button, The red RESET button will pop out exposing the word TRIP. Power is now off
at the outlets protected by the GFCI, indicating that the device is functioning properly.
If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician.
To restore power, push RESET button.
WARNING :
If the RESET button pops out during operation, stop the generator immediately and call a
qualified electrician for checking generator and the appliances.
Caution : To connect the appliance to locking
receptacle, insert the plug into the re-
ceptacle and turn it clockwise to lock.
Fig. 5-8
Table. 5-2
TWIST
elytSerepmAelcatpeceRgulpCAnoitpircseD
A02otpuA02-5AMENP02-5AMEN
tluaFdnuorG(ICFG
)retpurretnItiucriC
xelpud,elcatpeceR
)1CER(
A02otpuR02-41LAMENP02-41LAMEN
elcatpeceRgnikcoL
)2CER(
A03otpuR03-5LAMENP03-5LAMEN
elcatpeceRgnikcoL
)3CER(