Subaru Robin Power Products RGV6100 Portable Generator User Manual


 
-
52
-
10-4-3 REASSEMBLY
(1) Install the receptacles, no-fuse breaker, terminals, switches, etc. on the control panel and wire them.
NOTE : Circuit diagrams are shown in Section 12. Colored wires are used for easy identification, and are
of the correct capacity and size. Use heat-resistant type wires (permissible temperature range
75
°
C or over) in the specified gauge shown in the circuit diagrams.
(2) Install condensers, and diode rectifier into the front panel.
(3) Connect the wires of control panel components and front panel.
(4) Attach the control panel to the front panel.
M4 screw . . . 6 pcs. (RGV2800, RGV4100)
M4 screw . . . 7 pcs. (RGV6100)
euqrotgninethgiT
m-N5.1-2.1
mc-gk51-21
bl-tf9.01-7.8