Subaru Robin Power Products RGV6100 Portable Generator User Manual


 
-
29
-
8-2 AC OUTPUT MEASURING
Use a circuit like the shown in Fig.8-8 for measuring AC output. A hot plate or lamp with a power factor of
1.0 may be used as a load. Adjust the load and rpm. and check that the voltage range is as specified in
Table 8-2 at the rated amperage and rated rpm.
8-3 DC OUTPUT MEASURING
Measurement of DC output is executed with the switch turned ON while the current is regulated at 8.3A
by adjusting the load to the generator. If the voltage is within the range from 6V to 14V, the voltage output
is normal.
NOTE : If a battery is connected as a load to the generator, the DC output voltage will increase by
approximately 1 to 2 V. Therefore, carefully observe the electrolyte level and do not overcharge
the battery.
Fig. 8-8
Fig. 8-9
Table. 8-2
egatlovdetaRV021V042
egnaregatloVV231-801V462-612