John Deere AC-G6000DY Portable Generator User Manual


 
Service
26 Operator’s Manual
STORING GENERATOR
SHORT TERM (1-6 MONTHS):
1. Add diesel fuel conditioner and stabilizer at the specied concentration.
2. Run the unit for two (2) minutes to ensure the mixed fuel is in the entire fuel system. Close the fuel valve and run the
unit until it stops.
3. Clean the exterior surface of the generator and apply a rust inhibitor.
4. Store the generator in a dry, well ventilated place.
LONG TERM (MORE THAN 6 MONTHS):
1. Add diesel fuel conditioner and stabilizer at the specied concentration.
2. Run the generator until the fuel tank and carburetor is dry.
3. Slowly pull the recoil starter handle out to the point of resistance (the point in the compression stroke where the intake
and exhaust valves are closed). This helps to prevent rust while the engine is not in use.
4. Clean the exterior surface of the generator and apply a rust inhibitor.
5. Store the generator in a dry, well ventilated place.
WARNING: FUEL SHOULD BE DRAINED IN A WELL VENTILATED AREA AND STORED IN A CONTAINER
APPROVED FOR DIESEL FUEL.
Storage
SPECIFICATIONS
ITEM SPECIFICATION
AC-G6000DY
Engine Yanmar
Watts (AC) Rated 5000 watts
Watts (AC) Max. 6000 watts
Rated Voltage (AC) 120/240V
Max. Amperage 50/25
Cont. Amperage 41.7/20.8
Frequency 60 Hz
Fuel Tank Capacity 2.7 gal.
Run Time Hours /
Tank of Fuel* 6.5 hrs.
Battery for Electric Start #32-0058
* Rated at 0% Load
NOTE: Unit ratings are established based on operation at standard conditions of 60° F and at sea level. The
performance of the generator must be de-rated for temperature and altitude by 1% for every 10° F above
60° F and 3.5% for every 1000 feet above sea level. Due to the operational characteristics of the thermal
type circuit breaker, the power available from the generator will decrease slightly with a corresponding
increase in ambient temperature.
Due to continuing product improvements, specications are subject to change without notice.
Specications