Husqvarna SMB 70, SMB 70 E Chainsaw User Manual


 
English – 19
INSTALLATION
Band Cleaning Tank (FIG. 28)
The tank (3) is placed on the mounting located
on the right-hand side of the sawmill. The band
cleaning fluid flow is regulated with a continu-
ously variable manual valve on the tank (FIG.
28A).
The tank (3) can be easily removed from the
sawmill. The spiral hose is inserted through the
hole in the band guide (8) and is connected in
the hole on the plate mounted on the adjustable
band guide. The fluid can then run down and
clean the bandsaw blade.
Handlebars (FIG. 27)
Attach the handlebars with the start lever (5) at a
suitable height on the right-hand frame (25) and
tighten the screws to 10 Nm. Attach the weight
(A) to the rear end of the handlebars.
FIG. 27
FIG. 28