Gardena R40Li Lawn Mower User Manual


 
30 - English
3. INSTALLATION
6. Connect the guide wire to the boundary wire with
the help of a solderless coupler:
Insert the boundary wire in each of the holes in
the coupler. Insert the guide wire in the centre
hole in the coupler. Check that the wires are fully
inserted into the coupler so that the ends are
visible through the transparent area on the other
side of the coupler.
Use pliers to completely compress the button on
the coupler.
It does not matter which holes are used to
connect each wire.
7. Staple down/bury the connector in the lawn.
3.7 Checking the loop
Check the loop signal by inspecting the indicator lamp
on the charging station.
Steady green light = good signals.
Flashing blue light = interruption in the boundary
wire, no signal.
Flashing yellow light = interruption in the guide
wire, no guide signal.
Flashing red light = interruption in the charging
station's antenna plate, no remote signal
available. Contact GARDENA Central Service to
rectify. See MEMO on page 4.
Steady blue light = weak signal. This may
depend on the boundary wire being over 250 m in
length or that the wire is damaged. If the mower
still works, this is not a problem.
Steady red light = fault in a circuit board in the
charging station. Contact GARDENA Central
Service to rectify. See MEMO on page 4.
See 9.2 Indicator lamp in the charging station on page
58 if the lamp does not indicate a solid green light.
IMPORTANT INFORMATION
Test that the guide wire works using the
Calibrate guide (3-5) function before using the
mower. See 3.8 First start-up and calibration on
page 31.
IMPORTANT INFORMATION
The guide wire may not cross the boundary
wire, for instance a boundary wire that is laid
out to an island.