CAT Titan 250 Portable Generator User Manual


 
Turbomachinery Package Specification Titan 250 Generator Set
Generator acceptance test report
American Society of Mechanical Engineers (ASME) data reports, as applicable
Solar’s Certificate of Compliance
If specified on the final project ITP, the QC data book may also include the following
documents at additional cost and increased delivery time:
Engine rotor balance record
Engine casing leak test record
Documentation from suppliers of major package components such as oil coolers,
oil filters, gearboxes and driven equipment
Optional electrical device list when applicable
Third-Party Certificates and Declarations of Conformity when applicable
17.5.2 Torsional Analysis Report (Optional)
A torsional analysis can be performed on the entire drive train to determine if there are
any significant torsional resonance conditions within ±10% of the operating speed range.
If a resonance condition (interference) is found, then a fatigue analysis is performed to
confirm the resonance will not cause fatigue failure in the shafting.
17.5.3 Lateral Analysis Report (Optional)
A lateral forced response analysis of the driven equipment can be performed to confirm
that any lateral critical speeds aren’t close enough to the operating speed range to cause
lateral vibration problems.
17.5.4 Operation and Maintenance Instruction Manual
The Operation and Maintenance Instruction Manual (OMI) provides descriptive and
instructional data for operating and servicing the turbomachinery package. General,
functional, and component descriptions of the turbine engine and associated package
systems with supporting illustrations are included in four volumes:
Systems Operator's Guide - Intended for the equipment operator, the systems
operator’s guide provides familiarization with controls and indicators, operating
procedures, and safety precautions to ensure safe equipment operation.
Maintenance Instructions - Intended for maintenance and field service
personnel, the maintenance instructions include preventive and corrective
procedures, including periodic inspection requirements, alignment procedures,
cleaning procedures, removal and installation procedures, adjustment
procedures, and tolerances.
Supplementary Data - Provided in the form of supplier manuals and data
sheets, the supplementary data provides descriptions of components and
assemblies not covered or fully discussed in the Maintenance Instructions
volume. Due to copyright restrictions, supplementary data from suppliers is
available in English only.
Illustrated Parts List - Provides part numbers, part names, quantities, reference
designators, and illustrations for locating and ordering parts.
Language - The OMI is provided in English. Other languages are available as an
option.
The OMI manual typically includes the following features:
Electronic viewing of data in a Windows environment
All volumes of the manual set on one CD-ROM
Search feature including full text search for supplier data
© 2008 Solar Turbines Incorporated. All rights reserved. TPS250GS/908 - Preliminary