CAT Titan 250 Portable Generator User Manual


 
Turbomachinery Package Specification Titan 250 Generator Set
Table 12. Accessory Equipment Specifications
120 VDC Battery and Charger System
Charger Type Floor Mount
Supply Voltage
380, 400, or 415 VAC, 50 Hz, 3 phase
460 VAC 60 Hz, 3 phase
Operating Temperature
-10 to 50°C (14 to 122°F)
Approximate Measurements (Charger)
Height 1.21 m (47.5 in.)
Width 0.98 m (38.5 in.)
Depth 0.65 m (25.5 in.)
Approximate Measurements (Lead Acid Batteries)
Height 1.78 m (5.8 ft)
Width 3.05 m (10.0 ft)
Depth 0.76 m (2.5 ft)
Approximate Measurements (NiCd Batteries)
Height 1.65 m (5.4 ft)
Width 4.83 m (15.8 ft)
Depth 1.02 m (3.3 ft)
Turbine Cleaning System
Water/Solvent Supply Pressure 85 to 100 psig (586 to 689 kPag)
Water/Solvent Supply Min. Temperature Ambient (Except In Extreme Cold)
On-Line Water/Solvent Flow Rate 2.3 – 4.5 L/min (0.6 – 1.2 gpm)
On-Line Propulsion Air Flow Rate 0.026 nm
3
/min (0.98 SCFM)
Package On-Line Triple Stage Strainer 300/200/100 Micron
On-Crank Water/Solvent Flow Rate 9.1 – 12.9 L/min (2.4 – 3.4 gpm)
On-Crank Propulsion Air Flow Rate 0.080 nm
3
/min (3.0 SCFM)
Package On-Crank Triple Stage Strainer 300/200/100 Micron
External Air Supply Clean Filtered Air
Air Supply Pressure 586 to 690 kPag (85 to 100 psig)
Turbine Cleaning Cart
Capacity 98 L (26 gal)
Tank Discharge Strainer 100 Micron
External Air Supply Clean Filtered Air
Air Supply Pressure 586 to 690 kPag (85 to 100 psig)
Approximate Measurements
Height 102 cm (40.2 in.)
Width 55 cm (21.7 in.)
Length 121.6 cm (47.87 in.)
Approximate Weight 86 kg (190 lb)
Tank Material 316L Stainless Steel
Certification
American Society of Mechanical Engineers
(ASME) or Pressure Equipment Directive (PED)
Electrical Certifications
CSA LR 77954
Solar’s Applicable Engineering Specifications
ES 9-62 Ingestive Cleaning Solar Gas Turbine Engines
ES 2416 DC Supply Systems
© 2008 Solar Turbines Incorporated. All rights reserved. TPS250GS/908 - Preliminary
60