Conguring the 6300 Control System
The 6300 control system requires higher power than other 240V systems. Dip switch #10 is factory set in the
ON position. This causes the heater to shut off when any pump is running in high speed. To allow the heater
to continue operating, dip switch #10 must be set to the OFF position.
To ensure your spa functions
properly, ensure the following
steps are performed before
starting your spa:
When installing the electrical
system, use a 60 amp GFCI.
Follow the GFCI wiring
diagram on the next page.
Have your dealer or installer
set dip switch #10 to the
OFF position on the circuit
board as shown at right.
Electrical Installation for 11 kW Heater
This applies to Ultimate Fitness spas with the 11 kW heater
only.
Two electrical services are required to heat the swim side of the
Fitness Spa.