Cal Flame Portable Spa Hot Tub User Manual


 
2009 Portable Spa
LTR20091000, Rev. A
Operating Your Spa
www.calspas.com
14
Setting the Temperature Lock
To activate the temperature lock:
Press the “UP” or “DOWN” button, “TIME”, “JETS
1”, then the “UP” button within three seconds.
The panel will display “TEMP LOCK” when the set
temperature is locked.
To unlock the set temperature:
Press the “UP” or “DOWN” button, “TIME”, “JETS
1”, and then the “DOWN” button.
Circulation Pump
This is an optional feature. The circulation pump will
come on when the system is checking temperature,
during lter cycles, during freeze conditions, or when
another pump is on.
Preset Filter Cycles
There are two lter cycles per day. The start and end
times of each cycle are programmable. To program,
set the time as instructed above, then press “MODE/
PROG” to advance to the next setting (or to exit
after the last setting). The default lter cycles are as
follows:
The rst lter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM.
The “FILTER 1” indicator icon will light when lter
1 is running.
The second lter cycle is automatically activated
at 8:00 PM and operates the pump until 10:00 PM.
The “FILTER 2” indicator icon will light when lter
2 is running.
The pump and the ozone generator will run during
ltration. At the start of each lter cycle, the blower
will run on highest speed for 30 seconds to clean out
the air channels. The lowest speed of pump 2 and
pump 3 will run for ve minutes. In the event of power
loss or shut down, the time of day will need to be
reset for lter cycles to run according to your desired
programming.
Clean up Cycle
When the pump or blower is turned on by a button
press, a clean-up cycle begins 30 minutes after the
pump or blower is turned off or times out. The pump
and the ozone generator will run for one hour.
Ozone
This is an optional feature. On most systems, the ozone
generator (if installed) runs during lter cycles (except
when pump 1 is operating at high speed on a non-circ
ulating system) and during clean-up cycles. On some
systems, the ozone generator operates whenever
the pump runs. If your system is congured with the
optional ozone disable feature, the ozone generator
will turn off for one hour any time a function button
(“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 44°F
within the heater, the pump automatically activates
to provide freeze protection. The equipment stays
on until four minutes after the sensors detect that
the spa temperature has risen to 45°F or higher. In
colder climates, an optional additional freeze sensor
may be added to protect against freeze conditions that
may not be sensed by the standard sensors. Auxiliary
freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and
without a four-minute delay in turnoff.
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder.
Message Frequency Action Required
rPH Every 7 days Test and adjust chemical levels per manufacturer’s instructions.
rSA Every 7 days Test and adjust chemical levels per manufacturer’s instructions.
rCL Every 30 days Remove, clean, and reinstall lter per manufacturer’s instructions.
rtg Every 30 days Test and reset GFCI per manufacturer’s instructions. Drain and rell
spa per manufacturer’s instructions.
rdr Every 90 days Drain and rell spa per manufacturer’s instructions.
rCO Every 180 days Clean and condition spa cover.
rCH Every 365 days Install a new lter.