Cal Flame Portable Spa Hot Tub User Manual


 
2009 Portable Spa
LTR20091000, Rev. A
Operating Your Spa
www.calspas.com
11
Jets
Press the Jets button:
Once to activate low speed pump.
Twice to activate high speed.
Three times to turn pump off.
Light
Press the Light button to turn on the light. Press it
once again to turn the light off. All optional lighting
such as the control panel light and cabinet perimeter
lighting is controlled by the Light button and will turn
on and off with the spa light.
Option
Press the Option button to turn on the pump 2. Press
it once again to turn off the pump 2 (6200 Controls
only).
6300 Controls - Pump 2 and Pump 3
Sequence
Press Option button once to activate high speed
pump 2.
Press Option button twice to activate high speed
pump 3 and high speed pump 2
Press 3 times to activate pump 3 hi speed only
Press 4 times to turn pumps off
Automatic Time outs
These features will automatically turn themselves off
during periods of continuous use:
Low speed pump After 4 hours
High speed pumps After 15 minutes
Optional circulation pump After 15 minutes
Optional turbo After 15 minutes
Spa light After 15 minutes
Setting Filtration Cycles
Your spa is programmed to lter twice a day. The rst
cycle will begin 6 minutes after the spa is turned on
and the second cycle 12 hours later. The factory has
programmed the cycle to last for 2 hours but this can
be switched to 4, 6, or 8 hours depending on your
requirements. To set ltration time, turn off the power
to the spa at the time of day you would like one of
the ltration cycles to begin then turn back on after
30 seconds. When power has been restored, press
the Temp button then the Jets button. Press Temp
button again to change the ltering cycle duration.
When desired duration is selected press the Jets
button to exit.
At the beginning of each ltering cycle the Turbo system
will run for approximately 30 seconds. The low speed
pump will run for the duration of the ltering cycle
and if an Ozone system is installed it will be activated.
During ltering, FC will appear on the main display.
Your new spa comes equipped with an electric heater. Following the directions listed below will ensure the
most efcient operation:
NOTE: This method is only for spa usage under two hours a week.
Keep the spa’s operating temperature 5˚F below the desired usage temperature when not in use. One
or two hours before use, set the temperature to the desired temperature.
If the spa usage exceeds two hours a week, the set temperature should remain at the desired usage
temperature.
The air venturis should be used sparingly. When open, water temperature drops quite rapidly and can
also dissipate chemicals.
Allowing the water temperature to lower more than 10˚F below the desired usage temperature and reheating
it prior to usage will cause the heater to operate longer than it normally would maintaining the desired
temperature. Doing this will increase your operating cost and makes your heater work more than necessary.