Subaru Robin Power Products RGX305, RGX305D, RGX405, RGX405D, RGX505, RGX505D Portable Generator User Manual


 
3. FEATURES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Lightweight, Compact
The Robin engine and revolving field generator designs provide added output power per weight and economical opera-
tion.
Centralized Control
The switches, meters, and receptacles are located together on a large-sized control box, and all operating controls are
located on top of the engine for easy generator operation.
Large 16-Liter Gas Tank
* 16-liter (4.2-gallon) fuel tank is provided for ten hours of operation for Model RGX305 or seven hours for Model
RGX405. (at the 50Hz rated output power)
*RGX505 can operate for six hours (at the 5OHz rated output power) with a full tank.
*The tank has a fuel gauge which shows the remaining amount of fuel in the tank.
Solid State Ignition System
*Unlike the point system, the solid state ignition system has no contact points so that maintenance due to point wear
is unnecessary and constant output power can be maintained for long.
*Increased spark energy makes starting easy.
Extra-Quiet Operation
*All models are equipped with a large-sized, low-noise muffler.
*All models have a cyclone type air cleaner of a low-noise, dustproof type.
Small Voltage Fluctuations by AVR (Automatic Voltage Regulator)
The automatic voltage regulator automatically adjusts the exciting current to hold voltage regulation down to less than
3%. This helps prolong product life without damaging the electric devices.
DC Output for Battery Charging
The generator can generate a DC output (12V, 1OOW) while generating an AC output so that batteries can be charged
during AC operation. In this case, make sure that the total AC and DC output does not exceed the rated output.
Full Power Switch
me dual voltage type has a full power switch as a standard component. The rated output can be generated at both
12OV (11 OV) and 240V (22OV).
Output Voltage Waveform Close to Sine Wave
The output voltage waveform is close to a sine wave and is free of surges so that the load will not be damaged.
Resistant to Inductive Load
Exciting power is obtained from the sub coil which is wound apart from the main coil. This means less output voltage
fluctuations against load variation, and thus a steady level of power. This feature is effective particularly for induction
motors, for example, which are subject to sharp current variation.
100% Copper Windings
The windings are made only of copper having low internal resistance. This feature also helps improve generator effi-
ciency and prolong generator life.
Easy Starting with Recoil Starter
No-Fuse Breaker for Troublefree Operation
-9-