Subaru Robin Power Products RGV7500 Portable Generator User Manual


 
11-4
NO
DC
OUTPUT
11-4-1
CHECK
THE
AC
OUTPUT.
Check the generator
by
following Step
11
-1
-1
through Step
11
-1
-2.
11-4-2
CHECK THE
DC
BREAKER.
If
the DC breaker turned
off
while charging
a
bat-
tery, check the cables for short-circuit or connec-
tion in reverse polarity before resetting it
on.
NOTE
:
If
the
DC
output
is
used
to
charge a large
capacity battery or
an
over-discharged
battery,
an
excessive current may flow
causing.
11-4-3
CHECK THE
WIRING.
Check all the wires to be connected correctly.
11-4-4
CHECK THE DIODE RECTIFIER.
Remove the control panel and check the diode
rectifier with
a
circuit tester.
Refer to Section
9-7
"DIODE RECTIFIER" for the
checking procedure.
Fig.
17-8
DIODE
RECTIFIER
~-
Fig.
71-9
11-44
CHECK THE DC COIL
Check the resistance between
two
brown leads from stator with
a
circuit tester.
If the resistance reading
is
much larger or smaller than the specified value, the
DC
coil of the stator
is
faulty. Replace stator with
a
new one.
Table.
11-3
-