Subaru Robin Power Products RGV7500 Portable Generator User Manual


 
5-2-9
GFCI
RECEPTACLE
After starting the engine, check the
GFCI
for'proper functioning by the following test procedure.
Push blue TEST button, The red
RESET
button
will
pop out exposing the word TRIP. Power is now
off
at
the outlets protected by the GFCI, indicating that the device is functioning properly.
If
TRIP
dose not appear when testing,
do
not
use
the generator. Call a qualified electrician.
To
restore power, push
RESET
button.
WARNING
:
If
the
RESET
button pops out during operation, stop the generator immediately and
call
a
qualified electrician for checking generator and the appliances.
5-2-10
CONNECTING
TO
DOMESTIC CIRCUITS
(HOUSE
WIRING)
Fig.
5-9
WARNING
:
This generator
is
a neutral grounded
type.
ff
a
generator
is
to
be connected to residential or commercial power lines, such as a stand-by
Faitwe
in
connection may result in death, personal injury, damage to generator, damage to appli-
ances, damage to the building's wiring or fire.
(a)
When
contnecting
a
Robin generator to
a
house wiring, generator output power must be taken from
.
power
source
during power outage,
all
connections must be made by
a
licensed electrician.
the
240V-4P
receptacle.
-
11
-