Subaru Robin Power Products RGV7500 Portable Generator User Manual


 
5-2-5
IDLE
CONTROL
UNIT
The idle control unit releases throttle valve when
the applied load current exceeds
0'.04A.
The
two
output wires from the main coils must go
through the
ZCT
in the same direction.
NOTE
:
It
is
normal that the engine speed goes up for
a
moment when you turn the key switch to
"STOP"
while the Auto Idle Switch
is
in
"ON"
position.
I
Fig.
5-6
5-2-6
NO-FUSE
BREAKER
The no-fuse breaker protects the generator
from
getting damage
by
overloading
or
short circuit in the
appliance. Table
5-1
shows the capacity of no-fuse breaker
by
each spec. and their object of protection.
I
SPECIFICATION
OBJECT
of
PROTECTION
NO-FUSE BREAKER
60
HZ-
120
V/
240V
'
Total
output
amperage
25
A
(2-Pole, 2-Element)
Table.
5-1
5-2-7
DC
CIRCUIT
BREAKER
The
10
ampere
DC
circuit breaker mounted on
the control panel protects whole
DC
circuit from
getting damage by overload or short circuit.
Fig.
5-7
-
9-