PAGE 26 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)
Filter Replacement
GB12BW/BS/BP LIGHTING SYSTEM — MAINTENANCE
1. Remove the balloon as described in the "Removing the
Lamp/Balloon" section.
2. Disconnect the lamp power cable.
3. Rotate the balloon/lamp base assembly so that the filter
is facing upwards. See Figure 42.
DO NOT replace filter immediately, allow a
sufficient amount of time for the lamp assembly
to cool down before changing filter.
WARNING - HOT SURFACE (LAMP FRAME)
Figure 42. Balloon/Lamp Placement
4. Using a small phillips-head screwdriver, remove the three
screws/washers that secure the air plate to the lamp base
(Figure 43). Remove air plate and filter.
Figure 43. Filter Removal
5. Install a new filter over the brace as shown in Figure 44.
Be sure to align the
cut of the filter
over the brace.
Figure 44. Filter Placement
Figure 45. Filter/Plate Install
CAUTION - FILTER ALIGNMENT
When placing the filter element, always align the cut of
the filter on top of the brace. This will keep the filter from
being dislodged and getting damaged.
BALLOON/LAMP
AIR
PLATE
FILTER
SCREW
AND
WASHER
LAMP
BASE
BRACE
FILTER
CUT
SCREW
AND
WASHER
6. Using a small phillips-head screwdriver, reinstall the three
screws/washers to secure the air plate to the lamp base
(Figure 45).