Multiquip GB12BW/BS/BP Landscape Lighting User Manual


 
PAGE 24 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)
GLOBUG GB12BW/BS/BP LIGHTING SYSTEM — MAINTENANCE
Replacing the Lamp
1. Allow lamp (Figure 32) 15-20 minutes to cool before chang-
ing.
Figure 34. Releasing Lamp Guard Locking Tabs
Figure 33. Rolling Up Balloon Enevlope
6. Remove lamp guard (Figure 35).
5. Release the lamp guard locking tabs (Figure 34).
LOCK
TAB
LAMP
GUARD
LOCK
TAB
LAMP
GUARD
Figure 35. Lamp Guard Removal
Figure 32. Hot Lamp Surface
1. If lamp assembly is attached to mast, loosen upper T-
handle bolt lock that secures the lamp to the mast and
remove.
2. Unzip the zipper at the bottom of the balloon. DO NOT
use excessive force when unzipping the balloon.
3. Place lamp/balloon assembly on a suitable work bench
that is free of dirt, and sharp objects that could damage
the balloon.
4. Roll the balloon envelope (Figure 33) upwards to expose
the lamp.
CAUTION - BALLOON ZIPPER SAFETY
DO NOT use excessive force when zipping or
unzipping the balloon. The possibility exists
of the zipper tearing, which would make the
balloon unusable.
BALLOON
ENVELOPE
ZIPPER
CAUTION - READ SAFETY GUIDELINES
Before performing any maintenance
procedures, be sure to READ the lamp,
balloon, and general safety guidelines in
this manual. Failure to
read
and
understand
these safety guidelines
could cause severe equipment damage and bodily harm.