BATTERY CHARGER WIRING DIAGRAM
BATTERY
CHARGER
LINE (L)
120VAC
INPUT
NEUTRAL (N)
GROUND (G)
NEMA 5-15, 15A, 120 VAC (HBL5278C/HUBBLE RECEPTACLE).
BLACK 14 AWG.
WHITE 14 AWG.
GREEN 14 AWG.
DC+
TO STARTER
“B”
TERMINAL
TO CHASSIS
GROUND
GREEN 16 AWG.
RED 16 AWG.
NOTES:
1
2
RECEPTACLE IS MOUNTED ON OUTPUT TERMINAL PANELASSY.
1
2
DC
Figure 73. Battery Charger Wiring Diagram