Jacuzzi J-280 Hot Tub User Manual


 
page 9

state or city building ordinances.
WARNING: In addition to maintenance of filters and water
chemistry, proper ventilation is recommended to reduce
the risk of exposure to viruses and bacteria that could be
present in the air or water. Consult a licensed architect
or building contractor to determine your specific needs if
installing your spa indoors.
5.0 Power Requirements
Jacuzzi
®
-
ibility of use when connected to the maximum electrical service listed

new spa to accept an electrical service other than the factory 50 Amp
operation setting. Note: Refer to pages 35-36 for circuit board congura-
tion details or contact your authorized Jacuzzi dealer.
All J-270/J-280 Models (60Hz)
240V/40A* 240V/50A** 240V/60A***
   
  
   
   
   
* will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high speed.
**
In 50A configuration, the heater will not operate while both jet pumps
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
*** In 60A configuration, the heater will operate while both jet pumps are
running in high speed.
Note: pump 2 runs only in high speed.