6. Examine the jet pumps on the sides of
the spa. There are two pump unions and two
gate valves per pump. Check to make sure the
pump unions are hand tight to prevent leaks.
Next, check the gate valves to make sure they
are fully opened (handles extended) and that the
red safety clips are snapped into place.
7. Remove the shipping bolts from the
base of each pump and rotate the swivel lock,
located at the rear of each pump, away from the
pump.
8. Next, look at the two circulation
pumps located at the bottom of the main
equipment compartment. Check the hose
clamp fitting where the plumbing attaches
to the pumps and make sure they are tight.
9. Remove the two bleeder valves located near the
filters on the top side of the spa. One is located near
the skimmer filter (see photo), and the other across the
spa near UltraPurefilter. Removing the bleeders
allows air to escape from the pumps while filling the
spa.