Dimension One Spas Bay Collection Hot Tub User Manual


 
Dimension One Spas - Bay Collection - Owner’s Manual
8
10. Remove the cap from the UltraPure
filter canister and the filter basket from the
skimmer canister.
UltraPure Filter
Skimmer Filter
11. Remove the
foam blocks securing
each filter.
12. Next, remove the filter from the
UltraPure canister and fill your hot tub
by placing a hose into the empty
UltraPure canister (for more details on
removing the filter, see the Filter Cleaning
section).
13. Fill the spa until the water level is about 6 inches below the top of the spa.
14. Once the spa is filled, replace the filters and turn on the
GFCI circuit breaker. The display screen on the control panel
will show the software version, followed by the software
number. The screen will then show the Spa menu. Dashed lines
will appear instead of the current temperature for the first 30
seconds.
15. On spas equipped with the Control Panel,
push the Jet Pump 1 Button once to turn on Pump 1. Let the
system run for 10 to 15 seconds to prime the pump, then press
the button again to turn it off. Repeat this process with pump 2
(if equipped).
16. If the jets do not start, there is air trapped in the plumbing lines. To eliminate the
trapped air, turn the pumps on and off several times to force the trapped air through the
pumps. If the jets still do not start, and the bleeder valves have been open for some time,
turn off the pumps and loosen the top pump unions (see illustration in step 6) slightly to let
any trapped air escape. Re-tighten the pump unions and turn the pumps on again. Turn the
pumps on and off several times until jets function properly.
Ozone bubbles will continue to rise from the skimmer compartment
UltraPure™ bleeder valve as long as the valve remains open. Once the jets are
working, be sure that the bleeder valve is closed tightly.
17. Once the jets are functioning properly, replace and close
the bleeder valves. Push up or down to enter the set point menu
and select the temperature you want the spa to heat or cool to.
Press Accept save changes.
The Display Window will not allow the temperature to be set above 104 F
(40C). However, if the water temperature exceeds 104 F (40 C), the
display will show the actual temperature. Never get in water if the
temperature exceeds 104 F (40 C).