Buhler 435 Lawn Mower User Manual


 
3-40
435/485/535
F3-122
SPEED
PTO RPM
AREA
START
STOP
CAL
% SLIP
DISTANCE
SELECT
F3-61
SPEED
PTO RPM
AREA
START
STOP
% SLIP
DISTANCE
SELECT
Fault Codes
In the event that a fault occurs within the tractor
electrical circuits, a malfunction warning symbol
“READ YOUR MANUAL,” (1) will flash on and off
and the code will be stored. The tractor is factory set
to display normal TPM functions and to store fault
codes.
To view fault codes as they occur, see “Turning active
fault display on/off” on page 3-42
Fault codes (2) will be displayed as flashing three-
digit number preceded by the letter “F.”
The fault code indicates the tractor circuit or sensor
in which the fault lies and the type of fault, e.g., short
circuit, open circuit, sensor failure, etc.
A complete detailed list of fault codes, their cause and
remedy may be seen in “Section 5 - Troubleshooting
Charts.
If necessary, contact your Buhler Versatile authorized
dealer and quote the fault code number.
Entering Fault Codes (Mode 2)
1. Hold the SELECT button (3) for two seconds
2. The TPM will display “1” (4) and “CAL (5).” Use
the UP/DOWN arrows (6) to change the display (4)
to “2”
3. Hold the SELECT
button (3) for two seconds to enter
into Mode 2 (Fault Codes)
Viewing Fault Codes
Touch the LEFT/RIGHT arrow buttons (7) to cycle
through stored fault codes. Each fault code will be
displayed along with the number of times the fault
has occurred, the engine hours of the most recent
occurrence, and the position of the fault code in the
stored list.
The illustration, F3-137 shows a typical fault code
display.
8 - Fault Code, 9 - Item number, 10 - Number
of occurrences, 11 - Engine hours of the last
occurrence.
To Exit Mode 2
Touch the START/STOP (8) button to return to the
calibration menu. Touch the START/STOP
button (8)
again to return to normal operation.
1
2
3
Section 3 - Operation
EIC - Tractor Performance Monitor (TPM)
4
5
6
7
8
F3-137
11
10
8
9