Ariens 915305 Lawn Mower User Manual


 
11 - 41
2 sets of contacts, one normally open, one normally closed. Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts manually activated. Contact
Resistance is 0.1-0.3 ohms when correct.
Normally open contacts manually activated. Contact
Resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally open. Contact resistance
is 0.1-0.3 ohms when correct.
Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally closed. Contact
resistance is 0.1-0.3 ohms when correct.
PTO Switch Off Run Start
Yellow/Red 11.50-13.00 Volts 11.50-13.00 Volts
Purple/white Connected to PTO Clutch
Purple 11.50-13.00 Volts 11.50-13.00 Volts
Brown/Yellow 11.50-13.00 Volts 11.50-13.00 Volts
Left Hand Neutral Switch Off Run Start
Brown/Yellow 11.50-13.00 Volts 11.50-13.00 Volts
White 11.50-13.00 Volts 11.50-13.00 Volts
Right Hand Neutral Switch Off Run Start
White 11.50-13.00 Volts 11.50-13.00 Volts
Red/Violet 11.50-13.00 Volts 11.50-13.00 Volts
Seat/PTO Relay Off Run Start
Purple 86 11.50-13.00 Volts 11.50-13.00 Volts
Pink 85 Connected to ground through seat switch
Yellow/Red 87 11.50-13.00 Volts 11.50-13.00 Volts
87A Not Used Not Used
Purple 30 11.50-13.00 Volts 11.50-13.00 Volts
Start Relay Off Run Start
Yellow/Red 86 11.50-13.00 Volts 11.50-13.00 Volts
Black 85 Connected to Ground
87 Not Used Not Used
White/Black 87A Connected to Ignition Module
Black 30 Connected to Ground